A Comprehensive analysis of E10 blends sourced from selected gasoline stations in the City of Batac, Ilocos Norte / (Record no. 23403)

MARC details
000 -LEADER
fixed length control field 02570nam a22001817a 4500
003 - CONTROL NUMBER IDENTIFIER
control field OSt
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20240919160253.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 240829b |||||||| |||| 00| 0 eng d
040 ## - CATALOGING SOURCE
Original cataloging agency MMSU
Transcribing agency ULS
100 ## - MAIN ENTRY--PERSONAL NAME
Personal name Ramos, Lachelle A.
245 ## - TITLE STATEMENT
Title A Comprehensive analysis of E10 blends sourced from selected gasoline stations in the City of Batac, Ilocos Norte /
Statement of responsibility, etc. Lachelle A. Ramos
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. City of Batac :
Name of publisher, distributor, etc. MMSU,
Date of publication, distribution, etc. 2024.
300 ## - PHYSICAL DESCRIPTION
Extent xiii, 95 leaves :
Dimensions 29 cm
500 ## - GENERAL NOTE
General note UTHESIS (Bachelor of Science in Agricultural and Biosystems Engineering)
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: leaves 65-70
520 ## - SUMMARY, ETC.
Summary, etc. The Philippines passed laws (Biofuels Act of 2006 and the Renewable Energy Act of 2008) to promote renewable energy and reduce reliance on fossil fuels, including mandating E10 blend starting in 2012. Existing literature extensively investigated the characteristics and impacts of E10 gasoline; however, a substantial void existed in the absence of compliance assessments during storage at fuel stations. Addressing this deficiency, this study, conducted in the City of Batac, Ilocos Norte, rigorously examined the storage and handling effects on E10 blends. Employing analytical testing by following the ASTM methods provided in the standard and descriptive analysis using a quantitative method, nine samples out of 21 underwent meticulous examination. From the analytical testing, none of the samples met the established standard, with at least three critical characteristics failing to meet the requirements. Although some samples satisfied criteria such as color, density, and distillation temperature, not all adhered to standards regarding appearance, lead content, water content, and percent residue. The survey component of the study identified ethanol absorption of water as a primary concern among respondents, accompanied by the absence of post-assessment distribution testing. These findings from both analytical testing and surveys are corroborative, rendering the samples non-compliant with established standards. Moreover, the investigation revealed systemic deficiencies in fuel testing and storage management across all fuel stations. Action is recommended to safeguard fuel integrity, emphasizing the implementation of policies governing the storage management of E10 gasoline in Underground Tanks (UGTs). Such measures are indispensable for ensuring compliance with standards and upholding public health and environmental sustainability amidst escalating concerns regarding fuel quality and safety.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Thesis/Dissertation
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Inventory number Barcode Date last seen Price effective from Koha item type Public note
          MMSU Main Library MMSU Main Library Theses and Dissertation Section 08/29/2024 6898 UTHESIS-6898 08/29/2024 08/29/2024 Thesis/Dissertation Room Use Only

© 2023 Mariano Marcos State University. All Rights Reserved.