MARC details
000 -LEADER |
fixed length control field |
02316nam a22001817a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
OSt |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20240919150038.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
240905b |||||||| |||| 00| 0 eng d |
040 ## - CATALOGING SOURCE |
Original cataloging agency |
MMSU |
Transcribing agency |
ULS |
100 ## - MAIN ENTRY--PERSONAL NAME |
Personal name |
Ancheta, Adrian Dave R...et.al. |
245 ## - TITLE STATEMENT |
Title |
Evaluation of a grid-tied solar-powered household in Bacsil South Laoag City / |
Statement of responsibility, etc. |
Adrian Dave R. Ancheta, Andres A. Andres, Harenz V. Aquino, Adrian Rafael A. Mateo |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Place of publication, distribution, etc. |
City of Batac : |
Name of publisher, distributor, etc. |
MMSU, |
Date of publication, distribution, etc. |
2024. |
300 ## - PHYSICAL DESCRIPTION |
Extent |
xx, 94 leaves : |
Dimensions |
29 cm |
500 ## - GENERAL NOTE |
General note |
UTHESIS ( Bachelor of Science in Electrical Engineering) |
504 ## - BIBLIOGRAPHY, ETC. NOTE |
Bibliography, etc. note |
Bibliography: leaves 70-72 |
520 ## - SUMMARY, ETC. |
Summary, etc. |
This study evaluates a 3.115 kW grid-tied solar PV system installed in a residential household in Brgy. 56-B Bacsil South, Laoag City. The main objectives were to determine the total initial cost of the system, monitor solar energy production and usage, project financial aspects over 25 years, compute the ROI and PBP, and assess the system’s effectiveness. Through a year of monitoring and data collection, including historical electricity profiles and solar generation records, the system's effectiveness was assessed. Results showed an initial investment of Php. 118,540.00, with the system producing 4432.19 kWh over the monitoring period. A 25-year projection estimated a gross saving of Php. 962,714.22, with an overall saving of Php. 802,540.79 after subtracting operating and maintenance costs. The investment was projected to be recovered in 5.0515 years, demonstrating a speedy payback period; and has an average annual return on investment of 27.7919%. Thus, the PBP for the optimal redesigned size of the solar PV system was projected to be 2 years, 2 months, and 15 hours and has an ROI of 62.2154%, which was faster and more effective than the actual size of the system presently installed. Redesigning the solar PV system, a kilowatt-peak value of 1533.65 kW, satisfies the optimal condition. The study recommends homeowners consider investing in grid-tied solar PV systems for long-term savings and future solar designers size systems according to load to maximize savings. Additionally, future research should explore different solar system types, such as hybrid and off-grid, using this study as a basis for comparison. |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
|
Koha item type |
Thesis/Dissertation |