Title Design, fabrication, and testing of a laboratory-scale 1-4 shell and tube heat exchanger /
Statement of responsibility, etc. Zaren Daicel A. Cristobal, Kristine Angela P. Danao, Alford Airon C. Velasco
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. City of Batac :
Name of publisher, distributor, etc. MMSU,
Date of publication, distribution, etc. 2024.
300 ## - PHYSICAL DESCRIPTION
Extent xx, 105 leaves :
Dimensions 29 cm
500 ## - GENERAL NOTE
General note UTHESIS ( Bachelor of Science in Chemical Engineering)
504 ## - BIBLIOGRAPHY, ETC. NOTE
Bibliography, etc. note Bibliography: leaves 76-79
520 ## - SUMMARY, ETC.
Summary, etc. The study was primarily conducted to design, fabricate, and test a laboratory scale 1-4 shell-and-tube heat exchanger (STHE) for school applications. The shell and tube equipment were constructed from 304 stainless steel, with a with an outside diameter of 260 mm (about 10.24 in), equipped with 44 Type 202 stainless steel tubes, with each tube being 4 feet in length, having 0.5 inch outside diameter, 0.44 inch inside diameter, and 1.5 mm thickness. The 1-4 STHE also featured tured fixed channel covers and fixed-tube sheet also constructed using 202 stainless steel sheet/tube. The layout of the tubes is arranged in 60° triangular pattern with a tube pitch of 0.75 inch and tube clearance of 0.25 inch. The tubes were supported in place by 3 baffles with spaced 12 inches between each other. Hot water at 95°C was the reference for the tube side inlet, and it leaves the STHE at 85°C. The target temperature for the water in the shell side was 50°C, from a shell inlet temperature of 25°C. Accessories such as thermocouples, pump, pipe, and hose were installed to test the STHE. Results of the study revealed that the fabricated STHE could heat the shell side fluid to a certain temperature given a certain amount of time but, the calculated average of qloss is equal to 26.86 kW and an efficiency of 52.9%.
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Source of classification or shelving scheme
Koha item type Thesis/Dissertation
Holdings
Withdrawn status Lost status Source of classification or shelving scheme Damaged status Not for loan Home library Current library Shelving location Date acquired Inventory number Barcode Date last seen Price effective from Koha item type Public note
          MMSU Main Library MMSU Main Library Theses and Dissertation Section 09/10/2024 6952 UTHESIS-6952 09/10/2024 09/10/2024 Thesis/Dissertation Room Use Only

© 2023 Mariano Marcos State University. All Rights Reserved.

Powered by Koha